Pharm
Maxon
search
Maxon
, Polyglyconate Suture
Category
Synthetic
Absorbable Suture
(monofilament)
Background
Properties
Improved handling over
Dexon
and
Vicryl
Excellent tensile strength (similar to PDS)
Background
Absorption (Hydrolysis)
Day 14: 81% of tensile strength
Day 28: 59% of tensile strength
Day 42: 30% of tensile strength
Day 180 to 210: Complete absorption of
Suture
References
Epperson in Pfenninger and Fowler (1994) Procedures for Primary Care Physicians, Mosby, Chicago, p. 3-11
Townsend (2001) Sabiston Textbook Surgery, p. 1552-3
Howell (1997) Emerg Med Clin North Am 15(2):417-25 [PubMed]
Moy (1991) Am Fam Physician 44(6):2123-8 [PubMed]